1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159
# Examples and Contributions
[A simple example](#simpleExample)  
[Multi Socket Electrical-Extension-Block](#mseeb)

<a name="simpleExample"></a>
## A very simple SDT example
In the ideal case, a large organization or SDO would define a widely-applicable set of [ModuleClasses](SDT_Components.md#ModuleClass), each of which could be used as needed to compose the description of a complex device. In order to show the appoach, this section will create a few example ModuleClasses based on - or inspired by - featues in the Echonet Lite protocol. Please note that the examples shown in this document are very "cut down" and by no means represent a true representation of Echonet Lite.

The Echonet Consortium has standardized their specifications within IEC/ISO (IEC62394, ISO/IEC24767-1, ISO/IEC24767-2, IEC62480, ISO/IEC14543-4-1, ISO/IEC14543-4-2, IEC62457) and they provide a comprehensive collection of various types of home appliances relevant to SmartGrid applications as ECHONET Device objects (see [https://echonet.jp/spec_object_rf_en/](https://echonet.jp/spec_object_rf_en/) ).

For the example in this document, to show re-use of ModuleClass definitions, two complex devices are chosen which have some common features and hence could be expected to both use some of the same ModuleClasses: an air conditioner and a washing machine.

<table>
<tr><th>Funtionality</th><th>Air Conditioner</th><th>Washing Machine</th></tr>
<tr><td>operationStatus</td><td>operates on/off</td><td>operates on/off</td></tr>
<tr><td>measuredCumulativePowerConsumption</td><td>the cumulative power consumption</td><td>the cumulative power consumption</td></tr>
<tr><td>installationLocation</td><td>this sets/reads a string text describing the location (room) of the air-conditioner.</td><td>this sets/reads a string text describing the location (room) of the washing machine.</td></tr>
<tr><td>setTimer</td><td>(not applicable. there is no preset start for an air-conditioner)</td><td>This sets/reads use the on/off timer</td></tr>
</table>

Based on the simplified example above, the two appliances will need the ModuleClasses below:

- *air-conditioner*: operationStatus, measuredCumulativePowerConsumption, installationLocation;
- *washing-machine*: operationStatus, measuredCumulativePowerConsumption, and setTimer. 

		<ModuleClass name="operationStatus">
			<Data>
				<DataPoint name="operationStatus" writable="true">
					<Doc>This property sets/reads the ON/OFF status.</Doc>
						<DataType>
							<SimpleType type="boolean"/> 
						</DataType>
				</DataPoint>
			</Data>
			<Events>
				<Event name="operationStatus">
				</Event>
			</Events>
		</ModuleClass>

		<ModuleClass name="measuredCumulativePowerConsumption">
			<Data>
				<DataPoint name="measuredCumulativePowerConsumption" writable="false">
					<Doc>This indicates cumulative power consumption of the device in increments of 0.001kWh.</Doc>
					<DataType>
						<SimpleType type="integer"/>
					</DataType>
				</DataPoint>
			</Data>
		</ModuleClass>

		<ModuleClass name="installationLocation">
			<Data>
				<DataPoint name="installationLocation" writable="true">
					<Doc>This property indicates the installation location</Doc>
					<DataType>
						<SimpleType type="string"/>
					</DataType>
				</DataPoint>
			</Data>
			<Events>
				<Event name="installationLocation"> </Event>
			</Events>
		</ModuleClass>

		<ModuleClass name="onTimerSetting">
			<DataPoint name="onTimer" writable="true">
				<Doc>Timer value (HH:MM)</Doc>
				<DataType>
					<SimpleType type="time"/>
				</DataType>
			</DataPoint>
		</ModuleClass>

The structure and the according SDT now looks like this:

<table>
<tr><td colspan="2" width="50%"><b>Example1.SDT</b></td></tr>
<tr><td> </td><td>Namespace information</td></tr>
<tr><td> </td><td>Modules (contains ModuleClasses)</td></tr>
<tr><td> </td><td>operationStatus<ul>
	<li>measuredCumulativePowerConsumption</li>
	<li>installationLocation</li>
	<li>onTimerSetting</li></ul></td></tr>
</table>

		<?xml version="1.0" encoding="iso-8859-1"?>
		<!-- Example1 SDT inspired by some Echonet Lite examples -->
		<Domain xmlns="http://homegatewayinitiative.org/xml/dal/3.0"
			xmlns:xi="http://www.w3.org/2001/XInclude"
			id="example1.SDT">
		
		<Modules>
		<!-- Various examples for module classes -->
		<ModuleClass name="operationStatus">
			<Data>
				<DataPoint name="operationStatus" writable="true">
					<Doc>This property sets the ON/OFF status.</Doc>
						<DataType>
							<SimpleType type="boolean"/> 
						</DataType>
				</DataPoint>
			</Data>
			<Events>
				<Event name="operationStatus">
				</Event>
			</Events>
		</ModuleClass>

		<ModuleClass name="installationLocation">
			<Data>
				<DataPoint name="installationLocation" writable="true">
					<Doc>This property indicates the installation location</Doc>
					<DataType>
						<SimpleType type="string"/>
					</DataType>
				</DataPoint>
			</Data>
			<Events>
				<Event name="installationLocation"> </Event>
			</Events>
		</ModuleClass>

		<ModuleClass name="measuredCumulativePowerConsumption">
			<Data>
				<DataPoint name="measuredCumulativePowerConsumption" writable="false">
					<Doc>This indicates cumulative power consumption of the device in increments of 0.001kWh.</Doc>
					<DataType>
						<SimpleType type="integer"/>
					</DataType>
				</DataPoint>
			</Data>
		</ModuleClass>

		<ModuleClass name="onTimerSetting">
			<DataPoint name="onTimer" writable="true">
				<Doc>Timer value (HH:MM)</Doc>
				<DataType>
					<SimpleType type="time"/>
				</DataType>
			</DataPoint>
		</ModuleClass>
			</Modules>
		</Domain>


---

<a name="mseeb"></a>
### Multi Socket Electrical-Extension-Block

This example is a specification for an imaginged device, a connected extension block with multiple power socket where each of the sockets are modeled as a 
separate *SubDevice*.

[mseeb.xml](../test/mseeb.xml)


---