diff --git a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md index a664cea72a7b2e92b73721f4a1b467da5f7127ad..43d2ae73f865343478b471ab8acdce904e8053f3 100644 --- a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md +++ b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md @@ -1963,13 +1963,9 @@ This ModuleClass provides capabilities for controlling the water strength of a d - #### 5.3.1.94 waterMeterAlarm This ModuleClass provides capabilities to provide alarm information of water meter, such as the alarm of low water flow. Once an alarm is fired, a notification should be sent out from the device and no historical alarm is stored locally, therefore no need to associate timestamp with the alarms. -<mark>Editor note: the following attributes are missing from the short name tables in 6.3</mark> - - **Table 5.3.1.94-1: DataPoints of waterMeterAlarm ModuleClass** |Name |Type |R/W |Optional |Unit |Documentation | @@ -2008,8 +2004,6 @@ This ModuleClass provides capabilities to provide alarm information of water met |vibrationSensorFault |xs:boolean |R |true | |Vibration sensor failure. | - - #### 5.3.1.95 waterMeterReportInfo This ModuleClass provides information of measurements of the water meter. @@ -6132,6 +6126,7 @@ In protocol bindings resource attributes names for data points of module classes |bodyLength |[bodyCompositionAnalyser](#53114-bodycompositionanalyser) |bodLh | |bone |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |bone | |brightness |[brightness](#53117-brightness) |brigs | +|buttonFault |[waterMeterAlarm](#53194-watermeteralarm)|butFt | |callerID |[phoneCall](#53164-phonecall) |calID | |callState |[phoneCall](#53164-phonecall) |calSe | |capacity |[battery](#53110-battery) |capay | @@ -6149,6 +6144,7 @@ In protocol bindings resource attributes names for data points of module classes |colourSaturation |[colourSaturation](#53124-coloursaturation) |colSn | |colourTemperature |[slcReportInfo](#53181-slcreportinfo) |colTe | |commFreqValue |[connectivity](#53125-connectivity) |coFVe | +|communicationAlarm |[waterMeterAlarm](#53194-watermeteralarm)|comAm | |component |[dmFirmware](#585-dmfirmware) |compt | |concentration |[glucometer](#53142-glucometer) |concn | |contextCarbohydratesAmount |[glucometer](#53142-glucometer) |coCAt | @@ -6186,6 +6182,7 @@ In protocol bindings resource attributes names for data points of module classes |dataType |[origin](#5394-origin) |datTe | |defaultValue |[numberValue](#53155-numbervalue), [textMessage](#53189-textmessage) |defVe | |defrost |[refrigeration](#53171-refrigeration) |defrt | +|demolitionAlarm |[waterMeterAlarm](#53194-watermeteralarm)|demAm | |description |[faultDetection](#53134-faultdetection), [dmDeviceInfo](#583-dmdeviceinfo), [localization](#5393-localization) |dc | |desiredHumidity |[relativeHumidity](#53172-relativehumidity) |desHy | |detectedTime |[overcurrentSensor](#53158-overcurrentsensor), [smokeSensor](#53182-smokesensor) |detTe | @@ -6222,8 +6219,14 @@ In protocol bindings resource attributes names for data points of module classes |heatingLevel |[heatingZone](#53144-heatingzone) |heaLl | |height |[height](#53145-height) |heigt | |highMagneticAlarm |[magneticSensorParameters](#53161-magneticsensorparameters)|hiMAm | -|highTemperatureAlarm |[temperatureAlarm](#53188-temperaturealarm)|hiTAm | -|highTemperatureAlarmThreshold |[temperatureAlarm](#53188-temperaturealarm)|hTATd | +|highFlowAlarm |[waterMeterAlarm](#53194-watermeteralarm)|hiFAm | +|highFlowAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|hFATd | +|highFlowDuration |[waterMeterAlarm](#53194-watermeteralarm)|hiFDn | +|highPressureAlarm |[waterMeterAlarm](#53194-watermeteralarm)|hiPAm | +|highPressureAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|hPATd | +|highTemperatureAlarm |temperatureAlarm](#53188-temperaturealarm), [waterMeterAlarm](#53194-watermeteralarm)|hiTAm | +|highTemperatureAlarmThreshold |[temperatureAlarm](#53188-temperaturealarm), [waterMeterAlarm](#53194-watermeteralarm)|hTATh | +|highTemperatureInnerAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|hTIAd | |horizontalAccuracy |[geoLocation](#53141-geolocation) |horAy | |horizontalDirection |[airFlow](#5314-airflow) |horDn | |humidity |[airQualitySensor](#5316-airqualitysensor) |humiy | @@ -6233,7 +6236,11 @@ In protocol bindings resource attributes names for data points of module classes |impactLevel |[impactSensor](#53147-impactsensor) |impLl | |impactStatus |[impactSensor](#53147-impactsensor) |impSs | |impedance |[bodyCompositionAnalyser](#53114-bodycompositionanalyser) |impee | +|impulseFault |[waterMeterAlarm](#53194-watermeteralarm)|impFt | |initialMagnetic |[magneticSensorParameters](#53161-magneticsensorparameters)|iniMc | +|innerErrorAlarm |[waterMeterAlarm](#53194-watermeteralarm)|inEAm | +|innerHighInternalTemperatureAlarm |[waterMeterAlarm](#53194-watermeteralarm)|iHITm | +|innerTemperatureSensorFault |[waterMeterAlarm](#53194-watermeteralarm)|iTSFt | |jobModes |[airConJobMode](#5313-airconjobmode), [airPurifierJobMode](#5315-airpurifierjobmode), [clothesWasherDryerJobMode](#53121-clotheswasherdryerjobmode), [clothesWasherJobMode](#53120-clotheswasherjobmode), [cookerHoodJobMode](#53126-cookerhoodjobmode), [dehumidifierJobMode](#53128-dehumidifierjobmode), [dishWasherJobMode](#53129-dishwasherjobmode), [robotCleanerJobMode](#53174-robotcleanerjobmode) [steamClosetJobMode](#53185-steamclosetjobmode), |jobMs | |jobStates |[runState](#53175-runstate) |jobSs | |kcal |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |kcal | @@ -6263,13 +6270,19 @@ In protocol bindings resource attributes names for data points of module classes |loudness |[acousticSensor](#5312-acousticsensor) |louds | |lowBattery |[battery](#53110-battery) |lowBy | |lowCreditAlarm |[gasMeterAlarm](#53139-gasmeteralarm) |loCAm | +|lowFlowAlarm |[waterMeterAlarm](#53194-watermeteralarm)|loFAm | +|lowFlowAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|lFATd | +|lowFlowDuration |[waterMeterAlarm](#53194-watermeteralarm)|loFDn | |lowGasAlarm |[gasMeterAlarm](#53139-gasmeteralarm) |loGAm | -|lowTemperatureAlarm |[temperatureAlarm](#53188-temperaturealarm)|loTAm | -|lowTemperatureAlarmThreshold |[temperatureAlarm](#53188-temperaturealarm)|lTATd | +|lowPressureAlarm |[waterMeterAlarm](#53194-watermeteralarm)|LoPAm | +|lowPressureAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|lPATd | +|lowTemperatureAlarm |[temperatureAlarm](#53188-temperaturealarm), [waterMeterAlarm](#53194-watermeteralarm)|loTAm | +|lowTemperatureAlarmThreshold |[temperatureAlarm](#53188-temperaturealarm), [waterMeterAlarm](#53194-watermeteralarm)|LTATd | |lqi |[signalStrength](#53178-signalstrength) |lqi | |machineStates |[runState](#53175-runstate) |macSs | |magneticDisturb |[gasMeterAlarm](#53139-gasmeteralarm) |magDb | |magneticSensitivityLevel |[magneticSensorParameters](#53161-magneticsensorparameters)|maSLl | +|magneticInterference |[waterMeterAlarm](#53194-watermeteralarm)|magIe | |manufacturer |[dmDeviceInfo](#583-dmdeviceinfo) |manur | |manufacturerDetailsLink |[dmDeviceInfo](#583-dmdeviceinfo) |maDLk | |manufacturingDate |[dmDeviceInfo](#583-dmdeviceinfo) |manDe | @@ -6341,6 +6354,7 @@ In protocol bindings resource attributes names for data points of module classes |powerStatus |[dmAgent](#582-dmagent) |powSs | |precision |[features](#5391-features) |precn | |presentationURL |[dmDeviceInfo](#583-dmdeviceinfo) |prURL | +|pressureSensorFault |[waterMeterAlarm](#53194-watermeteralarm)|prSFt | |previousChannel |[televisionChannel](#53186-televisionchannel) |preCl | |preWash |[clothesWasherJobModeOption](#53122-clotheswasherjobmodeoption) |preWh | |primaryName |[dmFirmware](#585-dmfirmware) |priNe | @@ -6370,6 +6384,9 @@ In protocol bindings resource attributes names for data points of module classes |resistance |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |resie | |retryInterval |[periodicalReportConfig](#53163-periodicalreportconfig) |retIl | |retryTimes |[periodicalReportConfig](#53163-periodicalreportconfig) |retTs | +|reverseFlowAlarm |[waterMeterAlarm](#53194-watermeteralarm)|reFAm | +|reverseFlowAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|rFATd | +|reverseFlowDuration |[waterMeterAlarm](#53194-watermeteralarm)|reFDn | |room |[location](#5392-location) |room | |roundingEnergyConsumption |[energyConsumption](#53132-energyconsumption) |roECn | |roundingEnergyGeneration |[energyGeneration](#53133-energygeneration) |roEGn | @@ -6409,6 +6426,7 @@ In protocol bindings resource attributes names for data points of module classes |step |[numberValue](#53155-numbervalue) |step | |stepValue |[audioVolume](#5318-audiovolume), [openLevel](#53156-openlevel), [temperature](#53187-temperature) |steVe | |storageAvailable |[dmAgent](#582-dmagent) |stoAe | +|storageFault |[waterMeterAlarm](#53194-watermeteralarm)|stoFt | |storageTotal |[dmAgent](#582-dmagent) |stoTl | |strength |[brewing](#53116-brewing) |streh | |subModel |[dmDeviceInfo](#583-dmdeviceinfo) |subMl | @@ -6424,6 +6442,7 @@ In protocol bindings resource attributes names for data points of module classes |swVersion |[dmDeviceInfo](#583-dmdeviceinfo) |sweVn | |systemTime |[dmAgent](#582-dmagent) |sysTe | |systolicPressure |[sphygmomanometer](#53183-sphygmomanometer) |sysPe | +|tamperAlarm |[waterMeterAlarm](#53194-watermeteralarm)|tamAm | |targetAltitude |[geoLocation](#53141-geolocation) |tarAe | |targetDuration |[timer](#53190-timer) |tarDn | |targetLatitude |[geoLocation](#53141-geolocation) |tarLe | @@ -6453,6 +6472,7 @@ In protocol bindings resource attributes names for data points of module classes |underVoltagePercent |[slcAlarm](#53179-slcalarm) |unVPt | |underVoltageThreshold |[slcAlarm](#53179-slcalarm) |unVTd | |unit |[temperature](#53187-temperature), [temperatureAlarm](#53188-temperaturealarm) |unit | +|urgencyButtonPush |[waterMeterAlarm](#53194-watermeteralarm)|urBPh | |uri |[printQueue](#53167-printqueue) |ur0 | |url |[sessionDescription](#53177-sessiondescription), [dmPackage](#588-dmpackage), [dmSoftware](#586-dmsoftware) |url | |useGrinder |[grinder](#53143-grinder) |useGr | @@ -6462,6 +6482,7 @@ In protocol bindings resource attributes names for data points of module classes |version |[dmPackage](#588-dmpackage), [dmSoftware](#586-dmsoftware) |versn | |verticalAccuracy |[geoLocation](#53141-geolocation) |verAy | |verticalDirection |[airFlow](#5314-airflow) |verDn | +|vibrationSensorFault |[waterMeterAlarm](#53194-watermeteralarm)|viSFt | |visceraFat |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |visFt | |voc |[airQualitySensor](#5316-airqualitysensor) |voc | |voltage |[battery](#53110-battery) |volte | @@ -6471,6 +6492,7 @@ In protocol bindings resource attributes names for data points of module classes |washTemp |[clothesWasherJobModeOption](#53122-clotheswasherjobmodeoption) |wasTp | |water |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |water | |waterFlowStrength |[waterFlow](#53193-waterflow) |waFSh | +|waterTemperatureSensorFault |[waterMeterAlarm](#53194-watermeteralarm)|wTSFt | |weight |[weight](#53199-weight) |weigt | |windDirection |[airQualitySensor](#5316-airqualitysensor) |winDn | |windSpeed |[airQualitySensor](#5316-airqualitysensor) |winSd |