diff --git a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md index bf88b71d60d1012443929c0f66db25f424aa49d3..9e3b3be31d57a4faa0bfccd013473695b48d80da 100644 --- a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md +++ b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md @@ -2021,14 +2021,13 @@ This ModuleClass provides capabilities to provide alarm information of water met #### 5.3.1.95 waterMeterReportInfo This ModuleClass provides information of measurements of the water meter. -<mark>Editor note: the following attributes are missing from the short name tables in 6.3</mark> - - **Table 5.3.1.95-1: DataPoints of waterMeterReportInfo ModuleClass** |Name |Type |R/W |Optional |Unit |Documentation | |-|-|-|-|-|-| -|dailyUseWaterTime |xs:integer |R |true |s |The total time of water consumption daily. | + + +TBC|dailyUseWaterTime |xs:integer |R |true |s |The total time of water consumption daily. | |cumulativeFlow |xs:float |R |false |m3 |The total consumption of water(since the activation of the meter). | |cumulativeFlowDaily |xs:float |R |true |m3 |The cumulative daily consumption of water (begins at 00:00). | |positiveCumulativeFlow |xs:float |R |true |m3 |The positive cumulative consumption of water daily (begins at 00:00). | @@ -2047,13 +2046,9 @@ This ModuleClass provides information of measurements of the water meter. |waterIntervalPressure |list of xs:float |R |true |bar |Water pressure records measured at the interval of "waterPressureInterval" described in clause [5.3.1.96](#53196-watermetersetting) per day. | - - #### 5.3.1.96 waterMeterSetting This ModuleClass provides capabilities to set service parameters for data sampling and reporting. -<mark>Editor note: the following attributes are missing from the short name tables in 6.3</mark> - **Table 5.3.1.96-1: DataPoints of waterMeterSetting ModuleClass** @@ -2068,7 +2063,6 @@ This ModuleClass provides capabilities to set service parameters for data sampli |intensiveReportStartTime |m2m:timestamp |RW |true | |The start time of data intensive report. | - #### 5.3.1.97 waterSensor This ModuleClass provides the capabilities to indicate whether or not water has been sensed, and raising an alarm if the triggering criterion is met. @@ -6213,6 +6207,7 @@ In protocol bindings resource attributes names for data points of module classes |fat |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |fat | |fatFreeMass |[bodyCompositionAnalyser](#53114-bodycompositionanalyser) |faFMs | |filterLifetime |[filterInfo](#53135-filterinfo) |filLe | +|flowInterval |[waterMeterSetting](#53196-watermetersetting) |floIl | |foamingStrength |[foaming](#53136-foaming) |foaSh | |frequency |[energyConsumption](#53132-energyconsumption) |freqy | |friendlyName |[dmDeviceInfo](#583-dmdeviceinfo) |friNe | @@ -6239,6 +6234,9 @@ In protocol bindings resource attributes names for data points of module classes |impactStatus |[impactSensor](#53147-impactsensor) |impSs | |impedance |[bodyCompositionAnalyser](#53114-bodycompositionanalyser) |impee | |initialMagnetic |[magneticSensorParameters](#53161-magneticsensorparameters)|iniMc | +|intensiveReportInterval |[waterMeterSetting](#53196-watermetersetting) |inRIl | +|intensiveReportStartTime |[waterMeterSetting](#53196-watermetersetting) |iRSTe | +|intensiveSampleInterval |[waterMeterSetting](#53196-watermetersetting) |inSIl | |jobModes |[airConJobMode](#5313-airconjobmode), [airPurifierJobMode](#5315-airpurifierjobmode), [clothesWasherDryerJobMode](#53121-clotheswasherdryerjobmode), [clothesWasherJobMode](#53120-clotheswasherjobmode), [cookerHoodJobMode](#53126-cookerhoodjobmode), [dehumidifierJobMode](#53128-dehumidifierjobmode), [dishWasherJobMode](#53129-dishwasherjobmode), [robotCleanerJobMode](#53174-robotcleanerjobmode) [steamClosetJobMode](#53185-steamclosetjobmode), |jobMs | |jobStates |[runState](#53175-runstate) |jobSs | |kcal |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |kcal | @@ -6373,6 +6371,7 @@ In protocol bindings resource attributes names for data points of module classes |resistance |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |resie | |retryInterval |[periodicalReportConfig](#53163-periodicalreportconfig) |retIl | |retryTimes |[periodicalReportConfig](#53163-periodicalreportconfig) |retTs | +|reverseFlowInterval |[waterMeterSetting](#53196-watermetersetting) |reFIl | |room |[location](#5392-location) |room | |roundingEnergyConsumption |[energyConsumption](#53132-energyconsumption) |roECn | |roundingEnergyGeneration |[energyGeneration](#53133-energygeneration) |roEGn | @@ -6474,6 +6473,8 @@ In protocol bindings resource attributes names for data points of module classes |washTemp |[clothesWasherJobModeOption](#53122-clotheswasherjobmodeoption) |wasTp | |water |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |water | |waterFlowStrength |[waterFlow](#53193-waterflow) |waFSh | +|waterPressureInterval |[waterMeterSetting](#53196-watermetersetting) |waPIl | +|waterTemperatureInterval |[waterMeterSetting](#53196-watermetersetting) |waTIl | |weight |[weight](#53199-weight) |weigt | |windDirection |[airQualitySensor](#5316-airqualitysensor) |winDn | |windSpeed |[airQualitySensor](#5316-airqualitysensor) |winSd |