diff --git a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
index 8313b84b6783bc66a16ba9298dd37ad360cc317d..6074a8976461319b7dab1e30a3a3972cd49aa7ca 100644
--- a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
+++ b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
@@ -1460,9 +1460,6 @@ This ModuleClass provides the status of the parking detector.
 #### 5.3.1.63 periodicalReportConfig
 This ModuleClass provides capabilities to set parameters of periodic report.
 
-<mark>Editor note: the following attributes are missing from the short name tables in 6.3</mark>
-
-
 **Table 5.3.1.63-1: DataPoints of periodicalReportConfig ModuleClass**
 
 |Name |Type |R/W |Optional |Unit |Documentation |
@@ -1474,7 +1471,6 @@ This ModuleClass provides capabilities to set parameters of periodic report.
 
 
 
-
 #### 5.3.1.64 phoneCall
 This ModuleClass provides the capability get or set the caller and recipient IDs as well as to initiate and terminate a call.
 
@@ -6180,6 +6176,7 @@ In protocol bindings resource attributes names for data points of module classes
 |altitude |[geoLocation](#53141-geolocation) |altie |
 |automode |[airFlow](#5314-airflow) |autoe |
 |availableChannels |[televisionChannel](#53186-televisionchannel) |avaCs |
+|backoffTime |[periodicalReportConfig](#53163-periodicalreportconfig) |bacTe |
 |basalMetabolism |[bodyCompositionAnalyser](#53114-bodycompositionanalyser) |basMm |
 |bath |[hotWaterSupply](#53146-hotwatersupply) |bath |
 |batteryThreshold |[battery](#53110-battery) |batTd |
@@ -6336,6 +6333,7 @@ In protocol bindings resource attributes names for data points of module classes
 |ozoneValueMG |[ozoneMeter](#53160-ozonemeter) |ozVMG |
 |ozoneValuePPM |[ozoneMeter](#53160-ozonemeter) |oVPPM |
 |password |[credentials](#53127-credentials) |pwd |
+|period |[periodicalReportConfig](#53163-periodicalreportconfig) |perid |
 |postalAddress |[location](#5392-location) |posAs |
 |power |[energyConsumption](#53132-energyconsumption) |power |
 |powerGenerationData |[energyGeneration](#53133-energygeneration) |poGDa |
@@ -6368,6 +6366,8 @@ In protocol bindings resource attributes names for data points of module classes
 |reliability |[features](#5391-features) |reliy |
 |remoteControlEnabled |[remoteControlEnable](#53173-remotecontrolenable) |reCEd |
 |resistance |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |resie |
+|retryInterval |[periodicalReportConfig](#53163-periodicalreportconfig) |retIl |
+|retryTimes |[periodicalReportConfig](#53163-periodicalreportconfig) |retTs |
 |room |[location](#5392-location) |room |
 |roundingEnergyConsumption |[energyConsumption](#53132-energyconsumption) |roECn |
 |roundingEnergyGeneration |[energyGeneration](#53133-energygeneration) |roEGn |