diff --git a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
index e8443216a9734e5f1298bfb384f25b9abb66fbc0..74b12f9bb47898bb7fb5230f61c8ac991d31dda9 100644
--- a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
+++ b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
@@ -851,9 +851,9 @@ This ModuleClass provides capabilities to monitor network connectivity.
 |dailyActivityTime |xs:integer |R |true |s |Daily communication time (Starts at 00:00h). |
 |dailyNumberOfConnections |xs:integer |R |true | |Daily number of connections (Starts at 00:00h). |
 |commFreqValue |xs:integer |R |true |MHz |Communication frequency value (commFreqValue) is the transmission frequency of the wireless signal. |
-|currentCycleBeginn |xs:datetime |R |true | |A timestamp that indicates the beginning of the current cycle for counting the transfer volume and transmission errors. |
-|currentCycleVolume |xs:integer |R |true |bytes |Number of bytes transferred since currentCycleBeginn. |
-|currentCycleTransmissionErrors |xs:integer |R |true | |Number of transmission errors since currentCycleBeginn. |
+|currentCycleBegin |xs:datetime |R |true | |A timestamp that indicates the beginning of the current cycle for counting the transfer volume and transmission errors. |
+|currentCycleVolume |xs:integer |R |true |bytes |Number of bytes transferred since currentCycleBegin. |
+|currentCycleTransmissionErrors |xs:integer |R |true | |Number of transmission errors since currentCycleBegin. |
 |minimumCommunicationLatency |xs:integer |R |true |s |The minimum time delay between the last communication attempt. |
 
 
@@ -1264,7 +1264,7 @@ This ModuleClass provides the status of water level (or other liquid) for an app
 
 |Name |Type |R/W |Optional |Unit |Documentation |
 |-|-|-|-|-|-|
-|liquitRemaining |[hd:enumLiquidLevel](#5624-hdenumliquidlevel) |R |false | |The remaining level of water or other liquid in an appliance (see clause [5.6.24](#5624-hdenumliquidlevel)). |
+|liquidRemaining |[hd:enumLiquidLevel](#5624-hdenumliquidlevel) |R |false | |The remaining level of water or other liquid in an appliance (see clause [5.6.24](#5624-hdenumliquidlevel)). |
 
 
 
@@ -1808,7 +1808,7 @@ This ModuleClass provides the capabilities to indicate the detection of smoke an
 |-|-|-|-|-|-|
 |alarm |xs:boolean |R |false | |The alarm is indicated as follows:<br />"True" indicates that smoke has been detected, "False" indicates a normal status, that means that smoke is not detected. |
 |detectedTime |m2m:timestamp |RW |true | |The date and time the smoke is detected. |
-|smokeThreshhold |xs:integer |RW |true |ppm |The threshold to trigger the alarm.  |
+|smokeThreshold |xs:integer |RW |true |ppm |The threshold to trigger the alarm.  |
 |currentValue |xs:integer |R |true | |The current data value of the smoke sensor. |
 |sensorFault |xs:boolean |R |true | |"True" indicates the sensor fault status of smoke sensor. "False" indicates the sensor fault of smoke sensor has been eliminated. |
 |lowVoltage |xs:boolean |R |true | |"True" indicates the low voltage status of smoke sensor. "False" indicates the low voltage alarm of smoke sensor has been eliminated. |
@@ -4084,7 +4084,7 @@ A card recharging machine is a device of the Railway Domain. The machine provide
 |billDeposit |[billDeposit](#531108-billdeposit) |1 |See clause [5.3.1.108](#531108-billdeposit). |
 |billWithdrawal |[billWithdrawal](#531109-billwithdrawal) |1 |See clause [5.3.1.109](#531109-billwithdrawal). |
 |coinDeposit |[coinDeposit](#531110-coindeposit) |1 |See clause [5.3.1.110](#531110-coindeposit). |
-|cashDispensor |[cashDispenser](#531111-cashdispenser) |1 |See clause [5.3.1.111](#531111-cashdispenser). |
+|cashDispenser |[cashDispenser](#531111-cashdispenser) |1 |See clause [5.3.1.111](#531111-cashdispenser). |
 |cardScanner |[cardScanner](#531112-cardscanner) |0..1 |See clause [5.3.1.112](#531112-cardscanner). |
 |connectivity |[connectivity](#53125-connectivity) |1 |See clause [5.3.1.25](#53125-connectivity). |
 |machineState |[runState](#53175-runstate) |1 |See clause [5.3.1.75](#53175-runstate). |
@@ -5749,7 +5749,7 @@ This ModuleClass is used to model the storage on a managed device.
 |fileSystem |xs:string |RW |true | |Indicates the filesystem type used on the mounted storage.  |
 |mountingPoint |xs:string |RW |true | |Indicates mounting point of the mounted storage.  |
 |mountOptions |xs:string |R |true | |Indicates additional file system specific and file system independent mount options that indicate specific behaviours of the mount point as well as the capabilities of the underlying file system. |
-|writable |xs:boolean |R |false | |Indicates whether the storage volume is mounted as read/write ("TRUE") or read-only ("FALSE").  |
+|writeable |xs:boolean |R |false | |Indicates whether the storage volume is mounted as read/write ("TRUE") or read-only ("FALSE").  |
 
 
 
@@ -6391,7 +6391,7 @@ In protocol bindings resource attributes names for data points of module classes
 |significantDigits |[energyConsumption](#53132-energyconsumption), [energyGeneration](#53133-energygeneration) |sigDs |
 |silentTime |[motionSensor](#53154-motionsensor) |silTe |
 |size |[binaryObject](#53111-binaryobject), [features](#5391-features) |size |
-|smokeThreshhold |[smokeSensor](#53182-smokesensor) |smoTd |
+|smokeThreshold |[smokeSensor](#53182-smokesensor) |smoTd |
 |softLeanMass |[bodyCompositionAnalyser](#53114-bodycompositionanalyser) |soLMs |
 |soilLevel |[clothesWasherJobModeOption](#53122-clotheswasherjobmodeoption) |soiLl |
 |speed |[airFlow](#5314-airflow) |speed |