diff --git a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md index bf88b71d60d1012443929c0f66db25f424aa49d3..0ceff4dda7dd7c23b510e803887a069467e9e35c 100644 --- a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md +++ b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md @@ -2021,9 +2021,6 @@ This ModuleClass provides capabilities to provide alarm information of water met #### 5.3.1.95 waterMeterReportInfo This ModuleClass provides information of measurements of the water meter. -<mark>Editor note: the following attributes are missing from the short name tables in 6.3</mark> - - **Table 5.3.1.95-1: DataPoints of waterMeterReportInfo ModuleClass** |Name |Type |R/W |Optional |Unit |Documentation | @@ -2048,7 +2045,6 @@ This ModuleClass provides information of measurements of the water meter. - #### 5.3.1.96 waterMeterSetting This ModuleClass provides capabilities to set service parameters for data sampling and reporting. @@ -6168,6 +6164,7 @@ In protocol bindings resource attributes names for data points of module classes |contextTester |[glucometer](#53142-glucometer) |conTr | |country |[dmDeviceInfo](#583-dmdeviceinfo) |couny | |cpuUsage |[dmAgent](#582-dmagent) |cpuUe | +|cumulativeFlowDaily |[waterMeterReportInfo](#53195-watermeterreportinfo) |cuFDy | |cupsNumber |[brewing](#53116-brewing) |cupNr | |current |[energyConsumption](#53132-energyconsumption) |currt | |currentAdfState |[autoDocumentFeeder](#5319-autodocumentfeeder) |cuASe | @@ -6191,6 +6188,7 @@ In protocol bindings resource attributes names for data points of module classes |dataModelType |[dmDataModelIO](#584-dmdatamodelio) |daMTe | |dataSourceID |[origin](#5394-origin) |daSID | |dataType |[origin](#5394-origin) |datTe | +|dailyUseWaterTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |dUWTe | |defaultValue |[numberValue](#53155-numbervalue), [textMessage](#53189-textmessage) |defVe | |defrost |[refrigeration](#53171-refrigeration) |defrt | |description |[faultDetection](#53134-faultdetection), [dmDeviceInfo](#583-dmdeviceinfo), [localization](#5393-localization) |dc | @@ -6239,6 +6237,7 @@ In protocol bindings resource attributes names for data points of module classes |impactStatus |[impactSensor](#53147-impactsensor) |impSs | |impedance |[bodyCompositionAnalyser](#53114-bodycompositionanalyser) |impee | |initialMagnetic |[magneticSensorParameters](#53161-magneticsensorparameters)|iniMc | +|intervalFlow |[waterMeterReportInfo](#53195-watermeterreportinfo) |intFw | |jobModes |[airConJobMode](#5313-airconjobmode), [airPurifierJobMode](#5315-airpurifierjobmode), [clothesWasherDryerJobMode](#53121-clotheswasherdryerjobmode), [clothesWasherJobMode](#53120-clotheswasherjobmode), [cookerHoodJobMode](#53126-cookerhoodjobmode), [dehumidifierJobMode](#53128-dehumidifierjobmode), [dishWasherJobMode](#53129-dishwasherjobmode), [robotCleanerJobMode](#53174-robotcleanerjobmode) [steamClosetJobMode](#53185-steamclosetjobmode), |jobMs | |jobStates |[runState](#53175-runstate) |jobSs | |kcal |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |kcal | @@ -6268,6 +6267,10 @@ In protocol bindings resource attributes names for data points of module classes |loudness |[acousticSensor](#5312-acousticsensor) |louds | |lowBattery |[battery](#53110-battery) |lowBy | |lowCreditAlarm |[gasMeterAlarm](#53139-gasmeteralarm) |loCAm | +|lowestFlowRate |[waterMeterReportInfo](#53195-watermeterreportinfo) |loFRe | +|lowestFlowRateTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |lFRTe | +|lowestReverseFlowRate |[waterMeterReportInfo](#53195-watermeterreportinfo) |lRFRe | +|lowestReverseFlowRateTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |lRFR0 | |lowGasAlarm |[gasMeterAlarm](#53139-gasmeteralarm) |loGAm | |lqi |[signalStrength](#53178-signalstrength) |lqi | |machineStates |[runState](#53175-runstate) |macSs | @@ -6305,6 +6308,7 @@ In protocol bindings resource attributes names for data points of module classes |muteEnabled |[audioVolume](#5318-audiovolume) |mutEd | |name |[dmPackage](#588-dmpackage), [dmSoftware](#586-dmsoftware) |name | |network |[threeDprinter](#5311-threedprinter) |netwk | +|negativeCumulativeFlow |[waterMeterReportInfo](#53195-watermeterreportinfo) |neCFw | |no2 |[airQualitySensor](#5316-airqualitysensor) |no2 | |noise |[airQualitySensor](#5316-airqualitysensor) |noise | |numberValue |[numberValue](#53155-numbervalue) |numVe | @@ -6333,10 +6337,15 @@ In protocol bindings resource attributes names for data points of module classes |parkingStatus |[parkingStatus](#53162-parkingstatus) |parSs | |password |[credentials](#53127-credentials) |pwd | |pci |[connectivity](#53125-connectivity) |pci | +|peakFlowRate |[waterMeterReportInfo](#53195-watermeterreportinfo) |peFRe | +|peakFlowRateTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |pFRTe | +|peakReverseFlowRate |[waterMeterReportInfo](#53195-watermeterreportinfo) |pRFRe | +|peakReverseFlowRateTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |pRFR0 | |period |[periodicalReportConfig](#53163-periodicalreportconfig) |perid | |pm1 |[airQualitySensor](#5316-airqualitysensor) | pm1 | |pm10 |[airQualitySensor](#5316-airqualitysensor) |pm10 | |pm25 |[airQualitySensor](#5316-airqualitysensor) | pm25 | +|positiveCumulativeFlow |[waterMeterReportInfo](#53195-watermeterreportinfo) |poCFw | |postalAddress |[location](#5392-location) |posAs | |power |[energyConsumption](#53132-energyconsumption) |power | |powerGenerationData |[energyGeneration](#53133-energygeneration) |poGDa | @@ -6373,6 +6382,7 @@ In protocol bindings resource attributes names for data points of module classes |resistance |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |resie | |retryInterval |[periodicalReportConfig](#53163-periodicalreportconfig) |retIl | |retryTimes |[periodicalReportConfig](#53163-periodicalreportconfig) |retTs | +|reverseIntervalFlow |[waterMeterReportInfo](#53195-watermeterreportinfo) |reIFw | |room |[location](#5392-location) |room | |roundingEnergyConsumption |[energyConsumption](#53132-energyconsumption) |roECn | |roundingEnergyGeneration |[energyGeneration](#53133-energygeneration) |roEGn | @@ -6474,6 +6484,8 @@ In protocol bindings resource attributes names for data points of module classes |washTemp |[clothesWasherJobModeOption](#53122-clotheswasherjobmodeoption) |wasTp | |water |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |water | |waterFlowStrength |[waterFlow](#53193-waterflow) |waFSh | +|waterIntervalPressure |[waterMeterReportInfo](#53195-watermeterreportinfo) |waIPe | +|waterIntervalTemperature |[waterMeterReportInfo](#53195-watermeterreportinfo) |waITe | |weight |[weight](#53199-weight) |weigt | |windDirection |[airQualitySensor](#5316-airqualitysensor) |winDn | |windSpeed |[airQualitySensor](#5316-airqualitysensor) |winSd |