diff --git a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
index 8313b84b6783bc66a16ba9298dd37ad360cc317d..8d16b39610a32e058da9bf909aecaed4efcc303c 100644
--- a/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
+++ b/TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
@@ -1764,9 +1764,6 @@ This ModuleClass provides capabilities to set service parameters.
 #### 5.3.1.81 slcReportInfo
 This ModuleClass provides information of status of the street light controller.
 
-<mark>Editor note: the following attributes are missing from the short name tables in 6.3</mark>
-
-
 **Table 5.3.1.81-1: DataPoints of slcReportInfo ModuleClass**
 
 |Name |Type |R/W |Optional |Unit |Documentation |
@@ -1786,8 +1783,6 @@ This ModuleClass provides information of status of the street light controller.
 |lampTechnology |xs:string |R |true | |A string that indicates the type of lamp technology that is used in the street lamps, e.g. "LED", "Tungsten", etc |
 
 
-
-
 #### 5.3.1.82 smokeSensor
 This ModuleClass provides the capabilities to indicate the detection of smoke and raising an alarm if the triggering criterion is met. 
 
@@ -6202,6 +6197,7 @@ In protocol bindings resource attributes names for data points of module classes
 |code |[faultDetection](#53134-faultdetection), [filterInfo](#53135-filterinfo) |code |
 |coldWash |[clothesWasherJobModeOption](#53122-clotheswasherjobmodeoption) |colWh |
 |colourSaturation |[colourSaturation](#53124-coloursaturation) |colSn |
+|colourTemperature |[slcReportInfo](#53181-slcreportinfo) |colTe |
 |component |[dmFirmware](#585-dmfirmware) |compt |
 |concentration |[glucometer](#53142-glucometer) |concn |
 |contextCarbohydratesAmount |[glucometer](#53142-glucometer) |coCAt |
@@ -6278,9 +6274,18 @@ In protocol bindings resource attributes names for data points of module classes
 |jobStates |[runState](#53175-runstate) |jobSs |
 |kcal |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |kcal |
 |keyNumber |[keypad](#53149-keypad) |keyNr |
+|lampTechnology |[slcReportInfo](#53181-slcreportinfo) |lamTy |
 |latitude |[geoLocation](#53141-geolocation) |latie |
 |level |[battery](#53110-battery) |lvl |
 |light |[alarmSpeaker](#5317-alarmspeaker) |light |
+|lightActivePower |[slcReportInfo](#53181-slcreportinfo) |LiAPr |
+|lightCurrent |[slcReportInfo](#53181-slcreportinfo) |ligCt |
+|lightApparentPower |[slcReportInfo](#53181-slcreportinfo) |liAPr |
+|lightDimmingValue |[slcReportInfo](#53181-slcreportinfo) |liDVe |
+|lightPolarizationAxis |[slcReportInfo](#53181-slcreportinfo) |liPAs |
+|lightPowerFactor |[slcReportInfo](#53181-slcreportinfo) |liPFr |
+|lightReactivePower |[slcReportInfo](#53181-slcreportinfo) |LiRPr |
+|lightVoltage |[slcReportInfo](#53181-slcreportinfo) |ligVe |
 |liquidLevel |[liquidLevel](#53150-liquidlevel) |liqLl |
 |liquidRemaining |[liquidRemaining](#53151-liquidremaining) |liqRg |
 |locale |[location](#5392-location) |locae |
@@ -6325,6 +6330,7 @@ In protocol bindings resource attributes names for data points of module classes
 |numberValue |[numberValue](#53155-numbervalue) |numVe |
 |object |[binaryObject](#53111-binaryobject) |objet |
 |objectType |[binaryObject](#53111-binaryobject) |objTe |
+|onlineStatus |[slcReportInfo](#53181-slcreportinfo) |onlSs |
 |openAlarm |[doorStatus](#53130-doorstatus) |opeAm |
 |openDuration |[doorStatus](#53130-doorstatus) |opeDn |
 |openLevel |[openLevel](#53156-openlevel) |opeLl |
@@ -6414,6 +6420,7 @@ In protocol bindings resource attributes names for data points of module classes
 |supportedPlayerModes |[playerControl](#53165-playercontrol) |suPMs |
 |supportedVerticalDirection |[airFlow](#5314-airflow) |suVDn |
 |supportURL |[dmDeviceInfo](#583-dmdeviceinfo) |suURL |
+|switchStatus |[slcReportInfo](#53181-slcreportinfo) |swiSs |
 |swVersion |[dmDeviceInfo](#583-dmdeviceinfo) |sweVn |
 |systemTime |[dmAgent](#582-dmagent) |sysTe |
 |systolicPressure |[sphygmomanometer](#53183-sphygmomanometer) |sysPe |
@@ -6445,6 +6452,7 @@ In protocol bindings resource attributes names for data points of module classes
 |voc |[airQualitySensor](#5316-airqualitysensor) |voc |
 |voltage |[battery](#53110-battery) |volte |
 |voltage |[energyConsumption](#53132-energyconsumption) |volte |
+|voltageFrequency |[slcReportInfo](#53181-slcreportinfo) |volFy |
 |volumePercentage |[audioVolume](#5318-audiovolume) |volPe |
 |washTemp |[clothesWasherJobModeOption](#53122-clotheswasherjobmodeoption) |wasTp |
 |water |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |water |