Skip to content
Snippets Groups Projects
Commit 799f9165 authored by Andreas Kraft's avatar Andreas Kraft
Browse files

Merge branch 'RDM-2025-0026-Adding_short_names_for_waterMeterReportInfo_MC' into R5

# Conflicts:
#	TS-0023-SDT_based_Information_Model_and_Mapping_for_Vertical_Industries.md
parents fbf476dc c8bdb059
No related branches found
No related tags found
1 merge request!40RDM-2025-0026-Adding_short_names_for_waterMeterReportInfo_MC
...@@ -2008,8 +2008,6 @@ This ModuleClass provides capabilities to provide alarm information of water met ...@@ -2008,8 +2008,6 @@ This ModuleClass provides capabilities to provide alarm information of water met
#### 5.3.1.95 waterMeterReportInfo #### 5.3.1.95 waterMeterReportInfo
This ModuleClass provides information of measurements of the water meter. This ModuleClass provides information of measurements of the water meter.
<mark>Editor note: the following attributes are missing from the short name tables in 6.3</mark>
**Table 5.3.1.95-1: DataPoints of waterMeterReportInfo ModuleClass** **Table 5.3.1.95-1: DataPoints of waterMeterReportInfo ModuleClass**
|Name |Type |R/W |Optional |Unit |Documentation | |Name |Type |R/W |Optional |Unit |Documentation |
...@@ -6100,6 +6098,7 @@ In protocol bindings resource attributes names for data points of module classes ...@@ -6100,6 +6098,7 @@ In protocol bindings resource attributes names for data points of module classes
|cpuUsage |[dmAgent](#582-dmagent) |cpuUe | |cpuUsage |[dmAgent](#582-dmagent) |cpuUe |
|cr6 |[waterQualityMonitor](#53198-waterqualitymonitor) |cr6 | |cr6 |[waterQualityMonitor](#53198-waterqualitymonitor) |cr6 |
|cu |[waterQualityMonitor](#53198-waterqualitymonitor) |cu | |cu |[waterQualityMonitor](#53198-waterqualitymonitor) |cu |
|cumulativeFlowDaily |[waterMeterReportInfo](#53195-watermeterreportinfo) |cuFDy |
|cupsNumber |[brewing](#53116-brewing) |cupNr | |cupsNumber |[brewing](#53116-brewing) |cupNr |
|currency |[billDeposit](#531108-billdeposit), [cashDispenser](#531111-cashdispenser), [coinDeposit](#531110-coindeposit), [prePaidCardReader](#531107-prepaidcardreader) |curry | |currency |[billDeposit](#531108-billdeposit), [cashDispenser](#531111-cashdispenser), [coinDeposit](#531110-coindeposit), [prePaidCardReader](#531107-prepaidcardreader) |curry |
|current |[energyConsumption](#53132-energyconsumption) |currt | |current |[energyConsumption](#53132-energyconsumption) |currt |
...@@ -6124,6 +6123,7 @@ In protocol bindings resource attributes names for data points of module classes ...@@ -6124,6 +6123,7 @@ In protocol bindings resource attributes names for data points of module classes
|dataModelType |[dmDataModelIO](#584-dmdatamodelio) |daMTe | |dataModelType |[dmDataModelIO](#584-dmdatamodelio) |daMTe |
|dataSourceID |[origin](#5394-origin) |daSID | |dataSourceID |[origin](#5394-origin) |daSID |
|dataType |[origin](#5394-origin) |datTe | |dataType |[origin](#5394-origin) |datTe |
|dailyUseWaterTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |dUWTe |
|defaultValue |[numberValue](#53155-numbervalue), [textMessage](#53189-textmessage) |defVe | |defaultValue |[numberValue](#53155-numbervalue), [textMessage](#53189-textmessage) |defVe |
|defrost |[refrigeration](#53171-refrigeration) |defrt | |defrost |[refrigeration](#53171-refrigeration) |defrt |
|demolitionAlarm |[waterMeterAlarm](#53194-watermeteralarm)|demAm | |demolitionAlarm |[waterMeterAlarm](#53194-watermeteralarm)|demAm |
...@@ -6201,6 +6201,7 @@ In protocol bindings resource attributes names for data points of module classes ...@@ -6201,6 +6201,7 @@ In protocol bindings resource attributes names for data points of module classes
|intensiveReportInterval |[waterMeterSetting](#53196-watermetersetting) |inRIl | |intensiveReportInterval |[waterMeterSetting](#53196-watermetersetting) |inRIl |
|intensiveReportStartTime |[waterMeterSetting](#53196-watermetersetting) |iRSTe | |intensiveReportStartTime |[waterMeterSetting](#53196-watermetersetting) |iRSTe |
|intensiveSampleInterval |[waterMeterSetting](#53196-watermetersetting) |inSIl | |intensiveSampleInterval |[waterMeterSetting](#53196-watermetersetting) |inSIl |
|intervalFlow |[waterMeterReportInfo](#53195-watermeterreportinfo) |intFw |
|jobModes |[airConJobMode](#5313-airconjobmode), [airPurifierJobMode](#5315-airpurifierjobmode), [clothesWasherDryerJobMode](#53121-clotheswasherdryerjobmode), [clothesWasherJobMode](#53120-clotheswasherjobmode), [cookerHoodJobMode](#53126-cookerhoodjobmode), [dehumidifierJobMode](#53128-dehumidifierjobmode), [dishWasherJobMode](#53129-dishwasherjobmode), [robotCleanerJobMode](#53174-robotcleanerjobmode) [steamClosetJobMode](#53185-steamclosetjobmode), |jobMs | |jobModes |[airConJobMode](#5313-airconjobmode), [airPurifierJobMode](#5315-airpurifierjobmode), [clothesWasherDryerJobMode](#53121-clotheswasherdryerjobmode), [clothesWasherJobMode](#53120-clotheswasherjobmode), [cookerHoodJobMode](#53126-cookerhoodjobmode), [dehumidifierJobMode](#53128-dehumidifierjobmode), [dishWasherJobMode](#53129-dishwasherjobmode), [robotCleanerJobMode](#53174-robotcleanerjobmode) [steamClosetJobMode](#53185-steamclosetjobmode), |jobMs |
|jobStates |[runState](#53175-runstate) |jobSs | |jobStates |[runState](#53175-runstate) |jobSs |
|kcal |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |kcal | |kcal |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |kcal |
...@@ -6234,6 +6235,10 @@ In protocol bindings resource attributes names for data points of module classes ...@@ -6234,6 +6235,10 @@ In protocol bindings resource attributes names for data points of module classes
|lowFlowAlarm |[waterMeterAlarm](#53194-watermeteralarm)|loFAm | |lowFlowAlarm |[waterMeterAlarm](#53194-watermeteralarm)|loFAm |
|lowFlowAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|lFATd | |lowFlowAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|lFATd |
|lowFlowDuration |[waterMeterAlarm](#53194-watermeteralarm)|loFDn | |lowFlowDuration |[waterMeterAlarm](#53194-watermeteralarm)|loFDn |
|lowestFlowRate |[waterMeterReportInfo](#53195-watermeterreportinfo) |loFRe |
|lowestFlowRateTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |lFRTe |
|lowestReverseFlowRate |[waterMeterReportInfo](#53195-watermeterreportinfo) |lRFRe |
|lowestReverseFlowRateTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |lRFR0 |
|lowGasAlarm |[gasMeterAlarm](#53139-gasmeteralarm) |loGAm | |lowGasAlarm |[gasMeterAlarm](#53139-gasmeteralarm) |loGAm |
|lowPressureAlarm |[waterMeterAlarm](#53194-watermeteralarm)|LoPAm | |lowPressureAlarm |[waterMeterAlarm](#53194-watermeteralarm)|LoPAm |
|lowPressureAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|lPATd | |lowPressureAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|lPATd |
...@@ -6278,6 +6283,7 @@ In protocol bindings resource attributes names for data points of module classes ...@@ -6278,6 +6283,7 @@ In protocol bindings resource attributes names for data points of module classes
|muteEnabled |[audioVolume](#5318-audiovolume) |mutEd | |muteEnabled |[audioVolume](#5318-audiovolume) |mutEd |
|name |[dmPackage](#588-dmpackage), [dmSoftware](#586-dmsoftware) |name | |name |[dmPackage](#588-dmpackage), [dmSoftware](#586-dmsoftware) |name |
|network |[threeDprinter](#5311-threedprinter) |netwk | |network |[threeDprinter](#5311-threedprinter) |netwk |
|negativeCumulativeFlow |[waterMeterReportInfo](#53195-watermeterreportinfo) |neCFw |
|nh3nh4 |[waterQualityMonitor](#53198-waterqualitymonitor) |nh3n4 | |nh3nh4 |[waterQualityMonitor](#53198-waterqualitymonitor) |nh3n4 |
|no2 |[airQualitySensor](#5316-airqualitysensor) |no2 | |no2 |[airQualitySensor](#5316-airqualitysensor) |no2 |
|no3n |[waterQualityMonitor](#53198-waterqualitymonitor) |no3n | |no3n |[waterQualityMonitor](#53198-waterqualitymonitor) |no3n |
...@@ -6310,11 +6316,16 @@ In protocol bindings resource attributes names for data points of module classes ...@@ -6310,11 +6316,16 @@ In protocol bindings resource attributes names for data points of module classes
|password |[credentials](#53127-credentials) |pwd | |password |[credentials](#53127-credentials) |pwd |
|pb |[waterQualityMonitor](#53198-waterqualitymonitor) |pb | |pb |[waterQualityMonitor](#53198-waterqualitymonitor) |pb |
|pci |[connectivity](#53125-connectivity) |pci | |pci |[connectivity](#53125-connectivity) |pci |
|peakFlowRate |[waterMeterReportInfo](#53195-watermeterreportinfo) |peFRe |
|peakFlowRateTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |pFRTe |
|peakReverseFlowRate |[waterMeterReportInfo](#53195-watermeterreportinfo) |pRFRe |
|peakReverseFlowRateTime |[waterMeterReportInfo](#53195-watermeterreportinfo) |pRFR0 |
|period |[periodicalReportConfig](#53163-periodicalreportconfig) |perid | |period |[periodicalReportConfig](#53163-periodicalreportconfig) |perid |
|ph |[waterQualityMonitor](#53198-waterqualitymonitor) |ph | |ph |[waterQualityMonitor](#53198-waterqualitymonitor) |ph |
|pm1 |[airQualitySensor](#5316-airqualitysensor) | pm1 | |pm1 |[airQualitySensor](#5316-airqualitysensor) | pm1 |
|pm10 |[airQualitySensor](#5316-airqualitysensor) |pm10 | |pm10 |[airQualitySensor](#5316-airqualitysensor) |pm10 |
|pm25 |[airQualitySensor](#5316-airqualitysensor) | pm25 | |pm25 |[airQualitySensor](#5316-airqualitysensor) | pm25 |
|positiveCumulativeFlow |[waterMeterReportInfo](#53195-watermeterreportinfo) |poCFw |
|positionX |[touchScreen](#531106-touchscreen) | posiX | |positionX |[touchScreen](#531106-touchscreen) | posiX |
|positionY |[touchScreen](#531106-touchscreen) | posiY | |positionY |[touchScreen](#531106-touchscreen) | posiY |
|postalAddress |[location](#5392-location) |posAs | |postalAddress |[location](#5392-location) |posAs |
...@@ -6359,6 +6370,7 @@ In protocol bindings resource attributes names for data points of module classes ...@@ -6359,6 +6370,7 @@ In protocol bindings resource attributes names for data points of module classes
|reverseFlowAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|rFATd | |reverseFlowAlarmThreshold |[waterMeterAlarm](#53194-watermeteralarm)|rFATd |
|reverseFlowDuration |[waterMeterAlarm](#53194-watermeteralarm)|reFDn | |reverseFlowDuration |[waterMeterAlarm](#53194-watermeteralarm)|reFDn |
|reverseFlowInterval |[waterMeterSetting](#53196-watermetersetting) |reFIl | |reverseFlowInterval |[waterMeterSetting](#53196-watermetersetting) |reFIl |
|reverseIntervalFlow |[waterMeterReportInfo](#53195-watermeterreportinfo) |reIFw |
|room |[location](#5392-location) |room | |room |[location](#5392-location) |room |
|roundingEnergyConsumption |[energyConsumption](#53132-energyconsumption) |roECn | |roundingEnergyConsumption |[energyConsumption](#53132-energyconsumption) |roECn |
|roundingEnergyGeneration |[energyGeneration](#53133-energygeneration) |roEGn | |roundingEnergyGeneration |[energyGeneration](#53133-energygeneration) |roEGn |
...@@ -6468,6 +6480,8 @@ In protocol bindings resource attributes names for data points of module classes ...@@ -6468,6 +6480,8 @@ In protocol bindings resource attributes names for data points of module classes
|washTemp |[clothesWasherJobModeOption](#53122-clotheswasherjobmodeoption) |wasTp | |washTemp |[clothesWasherJobModeOption](#53122-clotheswasherjobmodeoption) |wasTp |
|water |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |water | |water |[bioElectricalImpedanceAnalysis](#53113-bioelectricalimpedanceanalysis) |water |
|waterFlowStrength |[waterFlow](#53193-waterflow) |waFSh | |waterFlowStrength |[waterFlow](#53193-waterflow) |waFSh |
|waterIntervalPressure |[waterMeterReportInfo](#53195-watermeterreportinfo) |waIPe |
|waterIntervalTemperature |[waterMeterReportInfo](#53195-watermeterreportinfo) |waITe |
|waterPressureInterval |[waterMeterSetting](#53196-watermetersetting) |waPIl | |waterPressureInterval |[waterMeterSetting](#53196-watermetersetting) |waPIl |
|waterTemperatureInterval |[waterMeterSetting](#53196-watermetersetting) |waTIl | |waterTemperatureInterval |[waterMeterSetting](#53196-watermetersetting) |waTIl |
|waterTemperatureSensorFault |[waterMeterAlarm](#53194-watermeteralarm)|wTSFt | |waterTemperatureSensorFault |[waterMeterAlarm](#53194-watermeteralarm)|wTSFt |
......
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!